MK Diamond MK-377 User Manual
Page 19
19
SETUP FOR OPERATION
1. Before connecting the MK-377 to a power supply, be sure the voltage, cycle
and phase meet the requirements of table below.
2. If using an extension cord, make sure the length and wire gauge
correspond to the requirements listed in the table on page 10. An extension
cord that is too small in wire gauge (diameter), or too long in length, will
cause the motor to overheat and could cause premature failure.
3. Before connecting the MK-377 to a power supply, be sure the voltage,
cycle and phase of the job site power source meet the requirements in the
table below.
4. Use an approved Ground Fault Circuit Interrupter (GFCI).
5. Do not cover the motor vents as this could lead to motor overheating.
VOLTAGE
120v
CYCLE
60Hz
PHASE
1-phase
In order to avoid breaker tripping, a 20 amp circuit breaker should be used.
NOTE:
(A)
Plug MK-377 into the GFCI (A
GFCI should always be used
when operating the MK-377)
(C)
Plug the GFCI into the
power source
CAUTION
MK-377 SAW OPERATION