GENERAL

CS1000 single pole plugs and connectors are

designed with safety and durability in mind. A finger

guard on the receptacle provides IP2X protection

from live parts. A locking pin prevents unwanted

disconnection. Each of the phases as well as the

neutral and ground are color coded and keyed to

prevent improper connection. Please follow the

instructions below to ensure the proper installation

and use of the product.

There are inherent dangers

associated with electrical

products. Failure to follow safety precautions can

result in serious injury or death. These instructions

must be followed to ensure the safe and proper

installation, operation and maintenance of the Meltric

devices. Before installation, disconnect all sources

of power to the circuit to eliminate the risk of

electrical shock.

RATINGS

The CS1000 series is for use in Non-Load Break

applications up to 400A at 600VAC (in North

America) or 1000VAC (in Europe – CE rated).

The CS1000 devices are NOT designed or

listed for current interruption.

INSTALLATION

These products should be installed by qualified

personnel in accordance with all applicable

local and national electrical codes.

Before starting, verify that the power is off, that the

product ratings are appropriate for the application,

and that the conductors meet code requirements.

NOTICE: For correct operation, the power cable

must not exert significant force on the product.

Wiring of the main conductor

Strip the conductor by approximately 1-1/8” depending on

the lug used. Crimp the threaded lug or the ferrule with

the appropriate die. Hexagonal crimping is recommended.

Tighten the threaded lug with a 21 mm wrench or

tighten the ferrule with a screw and washer with a

19 mm socket.

The tightening torque must not be transmitted

to the insulated casing. To avoid transmitting

torque to the device when securing the lugs, hold the

terminal in place with a 24 mm wrench.

While tightening the ferrule of the screw, maintain the

rear of the CS contact with a 21 mm wrench. Apply a

torque of 30 ft-lb (40 N-m).

Assembly of the handle

Screw handle onto the product and tighten the cable

gland with an appropriate tool. Block the rotation of

the handle with the supplied screw. Assemble as

shown below.

Assembly with adapter plate

Assemble the adaptor plate on the product and

tighten the M40 nut with an appropriate tool.

Align tabs and assemble as shown below.

Hole pattern for adapter plate

NOTICE: In order to maintain IP66/67 protection in

custom installations, watertight seals must be used

under the heads of the four mounting fasteners and

they must be retained by a lock washer and nut on

the inside of the box or panel. Alternatively, four

blind holes can be drilled and threaded to

accommodate #8-32 x 5/8” mounting screws. The

hole depth must be sufficient to achieve adequate

gasket compression.

Assembly on an inclined sleeve

(with adapter plate)

Assemble the adapter plate on the inclined sleeve.

Do not forget the gasket between the adaptor plate

and the inclined sleeve, and between the inclined

sleeve and the panel. Assemble as shown below.

When mounting on a wall or panel, position the inlet or

receptacle so that the locking pin or latch is at the top.

Assembly on a panel board

Direct assembly

Assemble the product on the panel board and tighten

the M40 nut supplied, with an appropriate tool. The

watertightness is achieved by the color-coded ring.

Color coded ring and color-coded ring for the lid

In order to achieve watertightness, do not forget the

color-coded ring at the rear of the inlet or receptacle

and the panel.

The

color-coded rings of receptacles and connectors

include a cap. The color-coded rings of plugs and

inlets do not include a cap.

Rated current and voltage markings

It is essential to indicate the current and voltage of

the main circuit on the supplied stickers. Apply the

stickers on or adjacent to the product so they can

easily be seen.

Color-coded ring on plug side

Adapter plate

Adapter

plate

Cap (partial

view)

Cap with color-coded ring on receptacle side

Inclined sleeve

M40 nut

M40 nut

Watertightness gaskets

Screw to block rotation

M40 nut

Watertightness gasket

Color-coded ring

Cap with Color-coded ring

Color-coded ring

2.25”

1.89”

1.89”

.19Ø mount

holes

OPERATING INSTRUCTIONS

Meltric Corporation

/ 4640 Ironwood Drive Franklin, WI 53132

Tel. : 800 433 7642 / Fax : 414 817 6161 / e-mail : [email protected]

INSCS1000 C

A manufacturer of products using Marechal technology

meltric

.com

CS1000

WARNING

Locking latch

Locking pin

Receptacle

(Female)

Plugs

(Male)

Earth

Phase1

Phase2

Negative

Phase3

Negative

Neutral