4 technical data, General data and operating conditions, Technical data – Lenze ECSZZxxxxxx User Manual
Page 36: 4technical data
4
Technical data
General data and operating conditions
EDKCSZZ040 DE/EN/FR 3.1
36
l
H1_Daten−Verlustleist_ECSZZ
4
Technical data
General data and operating conditions
Standards
Approval
UL 1283
Standard for Electromagnetic Interference Filters (File
No. E70122) for USA
Mains data
Mains types
With grounded neutral (TT/TN systems)
Operation permitted without restrictions
Other mains types
Observe instructions for special measures in the
documentation for the basic device!
Protection
Type of protection
EN 60529
IP 20
Not in the wire range of
the terminals
NEMA 250
Protection against contact to
type 1
Insulation resistance
EN 61800−5−1
Overvoltage category III
> 2000 m: Overvoltage category II
Leakage current
EN 61800−5−1
> 3.5 mA
Observe regulations
and safety instructions!
Ambient conditions
Temperature
Storage
−25 ... +60 °C
Transport
−25 ... +70 °C
Operation
−10 ... +55 °C
Current derating from +40 to +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating by 5 %/1000 m
Pollution
EN 61800−5−1
Pollution degree 2
Vibration resistance
EN 50178; IEC
61800−5−1;
Germanischer
Lloyd, general
conditions
Acceleration−resistant up to 1 g