3 types 8225 to 8227, Technical data – Lenze 8240 HVAC Series User Manual
Page 14

Technical Data
3-4
UOOuhäáã~_^NMMO
3.2.3
Types 8225 to 8227
120 % overload
Type
8225
4)
8226
8227
4)
Order no.
EVF8225-E-
V020
EVF8226-E-
V020
EVF8227-E-
V020
Mains voltage
V
rated
[V]
320 V - 0% ≤V
rated
≤440 V + 0% ;
45 Hz
¼ 65 Hz 0%
Alternative DC supply
V
DC
[V]
460 V - 0% ≤ V
DC
≤ 620 V + 0%
Mains current
with mains filter/mains choke
I
mains
[A]
119
144
185
Data for mains operation with 3 AC / 400 V / 50 Hz/60 Hz ; 460 V ≤ V
DC
≤ 620 V
Motor power (4 pole ASM)
ff
/
P
rated
[kW]
75
90
110
p
( p
)
off 4kHz/8kHz*
P
rated
[hp]
100
120
148
Output power U, V, W
off 4 kHz/8 kHz*
S
rated4
[kVA]
S
rated8
[kVA]
91.5
76.2
110
103.9
142
124.7
Output power +U
G
, -U
G
1)
P
DC
[kW]
0
28.1
40.8
Output
4 kHz*
I
rated4
[A]
135
159
205
p
current
8 kHz*
I
rated8
[A]
110
150
171
12 kHz*
I
rated12
[A]
88
120
126
16 kHz*
I
rated16
[A]
77
105
108
noise optimized 4 kHz*
I
rated4
[A]
110
150
159
5)
noise optimized 8 kHz*
I
rated8
[A]
76
5)
92
5)
100
5)
noise optimized 12 kHz*
I
rated12
[A]
66
82
90
noise optimized 16 kHz*
I
rated16
[A]
60
67
72
Max. output
f
4 kHz*
I
rated max4
[A]
165
225
270
p
current for
60s
2)
8 kHz*
I
rated max8
[A]
165
225
221
60s
2)
12 kHz*
I
rated max12
[A]
114
156
164
16 kHz*
I
rated max16
[A]
100
136
140
noise optimized 4 kHz*
I
rated max4
[A]
165
225
238
5)
noise optimized 8 kHz*
I
rated max8
[A]
114
5)
138
5)
150
5)
noise optimized 12 kHz*
I
rated max12
[A]
85
107
117
noise optimized 16 kHz*
I
rated max16
[A]
78
87
94
Motor voltage
3)
V
M
[V]
0 - 3 ×V
mains
/ 0Hz
¼ 50Hz, if required up to 480Hz
Power loss (Operation with I
Nx
)
P
v
[W]
1470
2100
2400
Power derating
[%/K]
[%/m]
40
°C < T
amb
< 50
°C: 2.5%/K
1000 m a.m.s.l < h ≤ 4000 m a.m.s.l: 5%/1000m
Field
f
Resolution
absolute
0.02 Hz
frequency
Digital setpoint selection
Accuracy
0.05 Hz
Analog setpoint selection
Linearity
0.5 % (max. selected signal level: 5 V or 10 V)
g
p
Temperature sensitivity
0
¼ 40 °C: +0.4 %
Offset
0 %
Weight
m [kg]
36.5
59
59
1)
This power can be additionally obtained when operating a matching motor
2)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here and
2 minutes base load with 75% I
Nx
.
3)
With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage
4)
Max. permissible ambient temperature during operation +35
°C
5)
must only be operated with C144 = -1- (automatic chopper frequency reduction at
J
max
= -5
°C). Ensure not to
exceed the currents.
*
Chopper frequency of the inverter
Show/Hide Bookmarks