Troubleshooting and fault elimination – Lenze EVF9383−EV User Manual
Page 34

Troubleshooting and fault elimination
Fault elimination
Controller in clamp operation
l
34
EDKVF93−05 EN 2.0
Adjustment
U
DC
t
C0912
³
t < C0912
t = C0912
0
1
IMP
9300vec142
Fig. 4−2
Influence of the delay time (C0912)
Switch−off threshold OU
Switch−on threshold OU
0
The period of time between exceeding the switch−off threshold OU and undershooting the
switch−on threshold OU equals or is higher than the delay time set in C0912.
After undershooting the switch−on threshold OU, the pulse inhibit is deactivated.
1
The period of time between exceeding the switch−off threshold OU and undershooting the
switch−on threshold OU is lower than the delay time set in C0912.
The pulse inhibit is deactivated after the delay time in C0912 has elapsed.
ƒ
The delay time in [ms] is set under C0912. The Lenze setting can be changed by the
factor 0.5 ... 2.