Technical data
Connection data
4
EDK82ZAFSC−100 DE/EN/FR 3.0
33
l
H1_Daten−Einsatzbed_Klima_FIF
4
Technical data
Connection data
X3/
Values
62
Resolution: 10 bit
Linearity distortion: ±0.5 %
Temperature distortion: 0.3 % (0
+60 °C)
Carrying capacity I
max
= 2 mA
8
Resolution: 10 bit
Linearity distortion: ±0.5 %
Temperature distortion: 0.3 % (0
+60 °C)
Input resistance
l
R
Input
> 50 k
W
(with voltage signal)
l
R
Input
= 250
W
(with current signal)
9
Carrying capacity I
max
= 10 mA
7
isolated from terminal X3/39 (GND2)
20
Load capacity:
S
I
max
= 40 mA
28
Input resistance: 3.3 k
W
1 = HIGH (+12
+30 V), PLC level, HTL
0 = LOW (0
+3 V), PLC level, HTL
E1
1)
E2
1)
E3
E4
39
isolated from terminal X3/7 (GND1)
A1
Load capacity:
I
max
= 10 mA, with internal supply
I
max
= 50 mA, with external supply
1)
Frequency input alternatively 0 10 kHz single−track or 0 ... 1 kHz two−track, config. via C0425
Operating conditions
Ambient conditions
Climate
Storage
IEC/EN 60721−3−1
1K3 (−25 to +60 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 to +70 °C)
Operation
Corresponding to the data of the Lenze basic device used (see
documentation of the basic device).
Pollution
EN 61800−5−1
Degree of pollution 2