Change/save parameters – Lenze 9371BB User Manual
Page 13

Change/Save parameters
MA9371BB 2.0
- 5 -
Change parameters
1. Change from the menus to the code level using the arrow keys
z
,
y
,
Y
or
Z
.
”Code” is displayed.
2. Select output AIN2/OUT (selection number 55) using
z
or
y
select code or
subcode.
3. Change to the parameter level using PRG.”Para” is displayed.
4. Select output AIN2/OUT (selection number 55) using
Y
or
Z
move the cursor
(small, black bar) under the number to be changed.
5. Select output AIN2/OUT (selection number 55) using
z
or
y
change number.
6. Repeat 4. and 5. to change other numbers, if ncessary.
7. Accept parameters. The way of accepting the changed parameterr is displayed in
front of the parameter:
Display in front of the parameter Controller uses the new value
p
immediately, during the change
SH+PRG
p
after pressing
T
+
V
.
Acknowledgement: ok in the display
SH+PRG
Press
S
to inhibit the controller.
Press
T
+
V
.
Acknowledgement: ok in the display
Press
U
to enable the controller.
8. Press
V
twice to go to the code level. ”Code” is displayed.
You can establish a user menu with max. 32 codes which you use
frequently under C0517.
•
The number before the comma is the code number.
•
The number after the comma is the subcode.
•
Code-subcode combinations are allowed only once.
Save parameter set
You have to save the modified parameters if you do not want to loose them after mains
disconnection.
•
You can establish up to four parameter sets, e.g. if you process different materials
on a machine or if this is required by different operating states (setup mode,
”stand-by”).
•
If you need only one parameter set, save the modifications permanently under
parameter set 1, since the controller automatically loads parameter set 1 after
mains connection.
How to proceed
1. Change from the menus to the code level using the arrow keys.
”Code” is displayed.
2. Select output AIN2/OUT (selection number 55) using
z
or
y
select C0003.
3. Change to the parameter level using PRG.
”Para” is displayed.
4. Set parameter to 1 using
z
or
y
(also possible during operation).
Note: If the parameter set is to be saved under another number, select 2, 3, or 4
instead of 1.
5. Press
T
+
V
.
”OK” is displayed for approx. 1 s.
Now your settings are saved permanently under parameter set 1 (or 2, 3. 4).
Further information on parameter setting can be obtained from the
corresponding Operating Instructions for the controller.
Show/Hide Bookmarks