6 technical data, Connection data, Technical data – Lenze E82ZAFAC001 User Manual
Page 41
Technical data
Connection data
6
EDK82ZAFAC−001 DE/EN/FR 5.0
41
l
H1_Daten−AlleMaßeInMM
6
Technical data
Connection data
X3.1/
1U/2U
1I/2I
Temperature error (0...+60°C) for level (ref. to current value):
l
0 ... +5 V:
l
0 ... +10 V:
l
−10 ... +10 V:
l
0/+4 ... +20 mA:
1 %
0.6 %
0.6 %
0.6 %
Linearity error:
±
0.5 %
A/D converter:
Resolution: 10 bit,
Error (ref. to limit value): 1 digit
º
0.1 %
Input resistance: Voltage signal: > 50 k
W
, current signal: 250
W
X3.2/
62
63
Resolution: 10 bit
Linearity error (ref. to current value):
±
0.5 %
Temperature error (0...+60 °C): 0.6 %
Load capacity (0 ... +10 V): I
max
= 2 mA
Load resistance (0/+4 ... +20 mA):
£
500
W
9
Load capacity: I
max
= 5 mA
X3.3/
A1
A2
Load capacity:
l
I
max
= 10 mA, with internal supply
l
I
max
= 50 mA, with external supply
A4
Load capacity: I
max
= 8 mA
f = 50 Hz ... 10 kHz
20
Load capacity:
S
I
max
= 60 mA
28
Input resistance: 3.2
kW
1 = HIGH (+12 ... +30 V), PLC level, HTL
0 = LOW (0 ... +3 V), PLC level, HTL
E1
1)
E2
1)
E3
E4
E5
E6
1)
Optional frequency input 0 ... 102.4 kHz (single or two−track), configuration via C0425