4 technical data, General data, Operating conditions – Lenze E82ZAFPC001 User Manual
Page 46: Technical data, 4technical data

4
Technical data
General Data
EDK82ZAFPC-001 DE/EN/FR 6.0
46
H1_Daten-IP20
4
Technical data
General Data
Field
Values
Order designation
E82ZAFPC001
PUO ID number
0x00DA
hex
Communication profile
(DIN 19245 part 1 and part 3)
PROFIBUS-DP-V0
Communication medium
RS485
Drive profile
”Drive technology 20” DRIVECOM profile, can be switched off
Network topology
Without repeater: line
With repeater: line or tree
PROFIBUS nodes
Slave
Baud rate [kbps]
9.6 ... 12000 (automatic recognition)
Process data words
1 ... 10 words
(16 bits per word)
DP user data length
4 parameter data words +
1 ... 10 process data words
Max. number of nodes
Standard: 32 (= 1 bus segment)
With repeater: 125
Max. cable length per bus
segment
1200 m (depending on the baud rate and cable type used)
External DC voltage supply
+24 V DC ±10 %, max. 80 mA
Operating conditions
Ambient conditions
Climate
Storage
IEC/EN 60721-3-1
1K3 (-25 to +60 °C)
Transport
IEC/EN 60721-3-2
2K3 (-25 to +70 °C)
Operation
Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
Pollution
EN 61800-5-1
Degree of pollution 2
Degree of protection
IP20 (protection against accidental contact according to NEMA 250 type 1)