beautypg.com

HYDAC AS 1000 User Manual

Page 6

background image

User Manual AS 1000

09.04.2008

6

6. Technical specification


Input data

Measuring range (saturation level)

0 .. 100 %

Measuring range (temperature)

-25 .. +100 °C

Operating pressure

max. 50 bar

Overload pressure

max. 630 bar

Parts in contact with the fluid

Stainless steel, Viton / or EPDM seal,
ceramic with vapour-deposited metal

Output data
Saturation level

Output signal

4 .. 20 mA

Calibration accuracy

≤ ± 2 % FS max.

Accuracy when measuring in fluids

≤ ± 3 % FS typ.

Pressure dependence

+ 0.025 % FS/bar

Output data
Temperature

Output signal

4 .. 20 mA

Accuracy

≤ ± 2% FS max.

Switch output 1 and 2

Output signal

PNP switch output 1 A max

Switch level

≤ U

B

Ambient conditions

Nominal temperature range (measurement of
saturation level)

0 .. + 90 °C

Ambient temperature range

-40 .. +100 °C

Temperature range of fluid

-40 .. +125 °C

Viscosity range

1 .. 5000 cSt

Flow velocity

< 5 m/s

Fluid compatibility

Mineral oil based fluids,
synthetic and natural esters

- mark

EN 61000-6-1, EN 61000-6-2
EN 61000-6-3, EN 61000-6-4

Protection class to DIN 40050

IP 67

Other data

Supply voltage

12 .. 32 V DC

Residual ripple supply voltage

≤ 5 %

Mechanical connection

G3/8A DIN 3852

Torque value

approx. 25 Nm

Electrical connection
Pin 1: +U

b

Pin 2: analogue output 1 / switch output 1
Pin 3: 0V / GND
Pin 4: analogue output 2 / switch output 2
Pin 5: HSI

M12x1, 5 pole

Reverse polarity protection of the supply voltage,
excess voltage, override and short circuit protection

Provided

Weight approx.

145

g

Note: FS (Full Scale) = relative to the full measuring range