Grayhill Modules Dry Contact and Mechanical Relay Output User Manual
Dry contact and mechanical relay output modules, Specifications by package style circuitry

Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
I/O Modules
Dry Contact and Mechanical Relay Output Modules
70L-ODC5R 70G-ODCR/OACRLY 70-ODCR/OACRLY 70M-ODCR
Package Style
Std (70-)
Mini (70M-)
G5 (70G-)
OpenLine
®
(70L-)
Specifications
Units
Isolation Voltage
1
Vrms
1500
1500
1500
1500
Vibration
2
MIL-STD-202
MIL-STD-202
MIL-STD-202
IEC68-2-6
Mechanical Shock
3
MIL-STD-202
MIL-STD-202
MIL-STD-202
IEC68-2-7
Storage Temp. Range
°C
-40 to 70
-40 to 70
-40 to 70
-40 to 70
Operating Temp. Range
°C
-40 to 70
-40 to 70
-40 to 70
-40 to 70
1
Field to logic and channel-to-channel if Grayhill racks are used.
2
MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec
2
, 10-150 Hz.
3
MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g.
SPECIFICATIONS By PACkAGE STyLE
CIrCUITry
Standard, Mini, G5
OpenLine
®
VAC/VDC
+VCC
INPUT
GROUND
1
2
3
4
5
AMP
LOAD
LOAD
Fuse and status LED in G5 modules only.
AMP
AMP
1
2
3
4
5
6
8
7
9
FEATUrES
• SPST, Normally Open
• UL, CSA Certified
• 1500 Vac Isolation
• G5 and OpenLine
®
Modules Provide
Replaceable 5x20mm Glass Fuse
• Built-in Status LED
• Lifetime Warranty
• Switch AC or DC with the Same Module
• Very Low Off-State Leakage Current for
AC loads
• No Off-State Leakage Current for DC
loads