beautypg.com

Door control, 24 v transformer – BEA 80.0011.02 User Manual

Page 9

background image

SIZE:

DRAWN BY:

TITLE: MC-25 WITH RECEIVERS, SEPARATE

POWER SUPPLY FOR MAGLOCK,
NIGHT MODE RELAY

A

NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS.

2) TYPE OF RELAY WILL BE DETERMINED BY MAGLOCK VOLTAGE (12 OR 24 VOLTS).

100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com

REV BY:

KJG

KJG

80.0020.02

SCALE:

DATE:

NONE

18 MAY 2005

PART NO:

SHEET
1 OF 1

COM

DOOR

CONTROL

ACT

RED COMMON
BLACK N/O

24 V

TRANSFORMER

COMPUTER SYSTEM

POWER SUPPLY

MAGLOCK

WHITE

GREEN

BLACK

RED

POWER 24 VAC
POWER 24 VAC

N / O

COMMON

WHITE

GREEN

BLACK

RED

POWER 24 VAC
POWER 24 VAC

N / O

COMMON

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM