beautypg.com

BEA 80.0011.02 User Manual

Mc-25, Dc-electric strike, 24 v transformer

background image

SIZE:

DRAWN BY:

TITLE: MC-25 WITH RECEIVER, ELECTRIC

STRIKE, PUSHPLATE, LOW ENERGY
AUTOMATIC DOOR APPLICATION

A

100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com

REV BY:

KJG

JEG

80.0011.02

SCALE:

DATE:

NONE

24 APR 2005

PART NO:

SHEET
1 OF 1

NOTE: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1.

2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF

ELECTRIC STRIKE.

GRAY

6
5
4

3
2

1

MC-25

RELAY 1

RELAY 2

RED COMMON

COM
N/O

BLACK

RED

GREEN

WHITE

POWER 24 VAC
POWER 24 VAC

N / O

COMMON

AUTOMATIC

DOOR CONTROL

ACT

-

+

DC-ELECTRIC

STRIKE

BRIDGE

RECTIFIER

~

~

+

-

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM

24 V

TRANSFORMER