beautypg.com

Door control, 24 v transformer, Optional bridge rectifier – BEA 80.0011.02 User Manual

Page 8

background image

SIZE:

DRAWN BY:

TITLE: MC-25 WITH ELECTRIC STRIKE,

APT. BUZZER RELAY/ FIRE ALARM

A

NOTES: 1) JUMPERS JP1,JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS ON RELAY OUTPUT #2.

2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT

DRAW OF ELECTRIC STRIKE.

4) BRIDGE RECTIFIER SUPPLIED BY OTHERS.

100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com

REV BY:

KJG

KJG

80.0019.02

SCALE:

DATE:

NONE

18 MAY 2005

PART NO:

SHEET
1 OF 1

COM

DOOR

CONTROL

ACT

RED COMMON
BLACK N/O

24 V

TRANSFORMER

COM
N/O

COM
N/O

OPTIONAL

BRIDGE

RECTIFIER

~

~

+

-

-

+

D/C ELECTRIC

STRIKE

VOLTAGE FOR

RELAY FROM

EXISTING APT.

BUZZER OR FIRE

ALARM SYSTEM

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM