beautypg.com

Table 38 – Georgia-Pacific APA Engineered Wood Construction Guide - Roofs User Manual

Page 12

background image

ENGINEERED WOOD CONSTRUCTION GUIDE

FORM NO. E30V

© 2011 APA – THE ENGINEERED WOOD ASSOCIATION

WWW.APAWOOD.ORG

69

Roof Construction

TABLE 38

ALLOWABLE SHEAR (POUNDS PER FOOT) FOR HORIZONTAL APA PANEL DIAPHRAGMS WITH
FRAMING OF DOUGLAS-FIR, LARCH OR SOUTHERN PINE

(a)

FOR WIND

(b)(c)

OR SEISMIC LOADING

(c)

Panel Grade

Common

Nail Size

(f)

Minimum

Nail

Penetration

in Framing

(in.)

Minimum

Nominal

Panel

Thickness

(in.)

Minimum

Nominal

Width of

Framing

Members

at

Adjoining

Panel

Edges and

Bound-

aries

(g)

(in.)

Blocked Diaphragms

Unblocked Diaphragms

Nail Spacing (in.) at

diaphragm boundaries

(all cases), at continuous

panel edges parallel

to load (Cases 3 & 4),

and at all panel

edges (Cases 5 & 6)

(d)

Nails Spaced 6" max. at

Supported Edges

(d)

Case 1 (No

unblocked

edges or

continuous

joints

parallel

to load)

All other

configurations

(Cases 2, 3,

4, 5 & 6)

6

4

2-1/2

(e)

2

(e)

Nail Spacing (in.) at

other panel edges

(Cases 1, 2, 3 & 4)

(d)

6

6

4

3

APA
STRUCTURAL I
grades

6d

(h)

1-1/4

5/16

2
3

185
210

250
280

375
420

420

475

165
185

125
140

8d

1-3/8

3/8

2
3

270

300

360
400

530
600

600

675

240
265

180
200

10d

(i)

1-1/2

15/32

2
3

320
360

425
480

640
720

730
820

285
320

215

240

APA RATED
SHEATHING
APA RATED
STURD-I-
FLOOR
and other
APA grades
except Species
Group 5

6d

(h)

1-1/4

5/16

2
3

170
190

225
250

335
380

380
430

150
170

110

125

3/8

2
3

185
210

250
280

375
420

420

475

165
185

125
140

8d

1-3/8

3/8

2
3

240
270

320
360

480
540

545

610

215

240

160
180

7/16

2
3

255
285

340
380

505

570

575

645

230
255

170
190

15/32

2
3

270

300

360
400

530
600

600

675

240
265

180
200

10d

(i)

1-1/2

15/32

2
3

290
325

385
430

575

650

655
735

255
290

190
215

19/32

2
3

320
360

425
480

640
720

730
820

285
320

215

240

(a) For framing of other species: (1) Find specific gravity for species

of lumber in the

AF&PA National Design Specification (NDS)

. (2)

Find shear value from table above for nail size for actual grade. (3)

Multiply value by the following adjustment factor: Specific Gravity

Adjustment Factor = [1 – (0.5 – SG)], where SG = specific gravity of

the framing. This adjustment shall not be greater than 1.

(b) For wind load applications, the values in the table above shall be

permitted to be multiplied by 1.4.

(c) For shear loads of normal or permanent load duration as defined

by the AF&PA NDS, the values in the table above shall be multiplied

by 0.63 or 0.56, respectively.

(d) Space nails maximum 12 inches o.c. along intermediate framing

members (6 inches o.c. when supports are spaced 48 inches o.c.

or greater). Fasteners shall be located 3/8" from panel edges.

(e) Framing at adjoining panel edges shall be 3" nominal or wider,

and nails shall be staggered where nails are spaced 2 inches o.c.

or 2-1/2 inches o.c.

(f) See

Table 5, page 14

, for nail dimensions.

(g) The minimum normal width of framing members not located at

boundaries or adjoining panel edges shall be 2".

(h) 8d is recommended minimum for roofs due to negative pressures

of high winds.

(i) Framing at adjoining panel edges shall be 3" nominal or wider,

and nails shall be staggered where 10d nails having penetration

into framing of more than 1-1/2" are spaced 3 inches o.c.

Note: Design for diaphragm stresses depends on direction of con-

tinuous panel joints with reference to load, not on direction of long

dimension or strength axis of sheet. Continuous framing may be in

either direction for blocked diaphragms.

Load

Lo

ad

Case 5

C

as

e

6

Continuous panel joints
Diaphragm boundary

Load

Lo

ad

Case 2

C

as

e

4

Load

Lo

ad

Case 1

C

as

e

3

Blocking typical

if used
Framing typical

Blocking typical

if used
Framing typical

Blocking typical

if used
Framing typical

Continuous panel joints
Diaphragm boundary

Continuous panel joints