5 dimensions and installation – Garland HO IN 3200 INDUCTION TEMPERATURE CONTROLLED BUILT-IN HOLD-LINE User Manual
Page 11

Installation
RTCSmp
Built-In
Temperature Controlled Hold-Line
Part # 4532287 Rev 4 (6/10/14)
11
4.5
Dimensions and Installation
4.5.1
Heat Retaining Plate Installation
The Heat Retaining Plate is to be flush-mounted. A support frame or support structure has to be custom designed
and built for housing the retaining plate(s).
4.5.1.1
Dimensions: RTCSmp HO IN800/1600/2400/3200 Heat Retaining Plate
(Measurements in mm and [inch])
4.5.1.2
Cut-Out Dimensions
Please review carefully the dimensions in section 4.4.1.1.
Refer to Detail A in section 4.4.1.1:
A. Cut-out dimension on the counter surface: 528 x 328 mm [20.79” x 12.91”]
NOTE:
Dimensions include widths for silicone joints on all four (4) sides.
Consider adjusting cutout dimensions based on mounting methods, see 4.5.1.3.
B. Recommended recess depth: minimum 8.00 to 8.64mm [0.315”to 0.34”]
C. Body Clearance (width x depth x height): 300 x 500 x 100mm / 11.81” x 19.69” x 3.94”
C
B
A
A
A
FRONT