4

Resistance to water absorption
After 7 days immersion 158 °F (70 °C)
Change in mass, %

ASTM D471
(top surface
only)

4.0 max.
2.0 typical

Resistance to microbial surface growth, rating (1 is very
poor, 10 is no growth)

ASTM D3274
2 yr S. Florida

9-10 typical

Field seam strength, lbf/in. (kN/m)
Seam tested in peel

ASTM D1876

25 (4.4) min.
60 (10.5) typical

Water vapor permeance, Perms

ASTM E96

0.10 max.
0.05 typical

Puncture resistance, lbf (kN)
(see supplemental section for additional
puncture data)

FTM 101C
Method 2031

250 (1.1) min. 45-mil
325 (1.4) typical 45-mil
300 (1.3) min. 60-mil
350 (1.6) typical 60-mil

Resistance to xenon-arc weathering

2

Xenon-Arc, 17,640 kJ/m

²

total radiant

exposure, visual condition at 10X

ASTM G155
0.70 W/m²

80 °C B.P.T.

No cracks
No loss of breaking
or tearing strength

1

Aging conditions are 28 days at 240 °F (116 °C) equivalent to 400 days at 176 °F (80 °C) for breaking strength,

elongation, tearing strength, ozone and puncture resistance

2

Approximately equivalent to 14,000 hours exposure at 0.35 W/m² irradiance B.P.T. is black panel temperature 6/07


SUPPLEMENTAL APPROVALS, STATEMENTS AND CHARACTERISTICS:

1. Flex TPO meets or exceeds the requirements of ASTM D6878

1

Standard Specification for

Thermoplastic Polyolefin Based Sheet Roofing.

2. Radiative Properties for E

NERGY

S

TAR

®, Cool Roof Rating Council (CRRC) and LEED™

TEST METHOD

WHITE
TPO

E

NERGY

S

TAR

initial solar reflectance

Solar Spectrum Reflectometer

0.87

E

NERGY

S

TAR

solar reflectance after 3 years

Solar Spectrum Reflectometer (after cleaning) 0.83

CRRC initial solar reflectance

ASTM C1549

0.79

CRRC solar reflectance after 3 years

ASTM C1549 (uncleaned)

0.70

CRRC initial thermal emittance

ASTM C1371

0.90

CRRC thermal emittance after 3 years

ASTM C1371 (uncleaned)

0.86

LEED thermal emittance

ASTM E408

0.95

SRI (Solar Reflectance Index)

ASTM E1980

110


An E

NERGY

S

TAR

compliant low slope roof product must have an initial solar reflectance of at least

0.65 and a 3 year aged solar reflectance of at least 0.50. Cleaning of the aged roof surface is permitted
by the ENERGY STAR test protocol.
The Cool Roof Rating Council (CRRC) does not specify minimums for reflectance or emittance but
they do require specific protocols for testing and reporting. Cleaning of the aged roof surface is not
permitted for determination of radiative properties after 3 years.

A LEED “point” may be earned if a roof material is E

NERGY

S

TAR

qualified and has a thermal

emittance of at least 0.90 as determined by ASTM E408.

California Title 24 requires an initial minimum reflectance of 0.70 and emittance of 0.75 as determined
by CRRC test protocol.