beautypg.com

7 terminal block, Terminal block – Bosch VIDEOJET X20 User Manual

Page 116

background image

116 en | Appendix

VideoJet X20

V3.5 | 2007.12

Installation and Operating Manual

Bosch Security Systems

8.7

Terminal Block

The terminal block has several contacts for:

4 alarm inputs

4 relay outputs

Serial data transmission

8.7.1

Pin Assignment

The pin assignment of the serial interface depends on the interface mode used (see

Section 5.27 COM1, page 74).

Connect each alarm input to a ground contact (GND) when connecting alarm inputs.

For the RM1 and RM2 contact specifications, see Section 4.3.10 Remote Indication of the

Connection Status, page 23.

For the backup power supply specifications, see Section 4.3.11 Backup Power Supply, page 24.

Contact

RS232 mode

RS422 mode

RS485 mode

CTS

CTS (clear to send)

RxD- (receive data minus)

Data-

TXD

TxD (transmit data)

TxD- (transmit data minus)

RTS

RTS (ready to send)

TxD+ (transmit data plus)

Data+

RXD

RxD (receive data)

RxD+ (receive data plus)

GND

GND (ground)

Contact

Function

IN1

Input alarm 1

IN2

Input alarm 2

IN3

Input alarm 3

IN4

Input alarm 4

GND

Ground

R1

Relay output 1

R2

Relay output 2

R3

Relay output 3

R4

Relay output 4

RM1

LED remote indicator

RM2

LED remote indicator

BP

Backup power supply

GND

Ground

+

10 to 30 V (power supply)

Ground