3 malfunctions with iscsi connections, Malfunctions with iscsi connections – Bosch VIDEOJET X20 User Manual
Page 113
VideoJet X20
Appendix | en
113
Bosch Security Systems
Installation and Operating Manual
V3.5 | 2007.12
8.3
Malfunctions with iSCSI Connections
The unit does not report
an alarm.
Alarm source is not selected.
Select possible alarm sources on
the Alarm Sources configuration
page.
No alarm response specified.
Specify the desired alarm
response on the Alarm
Connections configuration page,
change the IP address if
necessary.
Control of cameras or
other units is not
possible.
The cable connection between
the serial interface and the
connected unit is not correct.
Check all cable connections and
ensure all plugs are properly
fitted.
The interface parameters do not
match those of the other unit
connected.
Make sure that the settings of all
units involved are compatible.
The unit is not
operational after a
firmware upload.
Power failure during
programming by firmware file.
Have the unit checked by
Customer Service and replace if
necessary.
Incorrect firmware file.
Enter the IP address of the unit
followed by /main.htm in your
Web browser and repeat the
upload.
Malfunction
Possible causes
Recommended solution
Malfunction
Possible causes
Recommended solution
After connecting to the
iSCSI destination, no
LUNs are displayed.
Incorrect LUN mapping during
iSCSI system configuration.
Check the iSCSI system
configuration and reconnect.
After connecting to the
iSCSI destination, "LUN
FAIL" appears below a
node.
The LUN list could not be read,
as it was assigned to the wrong
network interface.
Check the iSCSI system
configuration and reconnect.
LUN mapping is not
possible.
Some iSCSI systems do not
support the use of an initiator
extension.
Delete the initiator extension on
the iSCSI configuration page.