Getdata, Setdata, Manual eks activex – EUCHNER ActiveX Module serial/USB User Manual
Page 9: Module serial / usb, 5 getdata, 6 setdata

Manual EKS ActiveX
®
Module serial / USB
3.4.5 getData
Description
Reading access to the internal memory area of the ActiveX
module, in which the read
data of the method Read or the event OnKey are stored.
Syntax
short = getData (short ByteIndex);
Comments
With the method getData, the internal memory area of the ActiveX
module can be
read. Upon triggering the events OnRead or OnKey, the key data are available in the
internal memory and can be read using getData. In the properties StartAdress and
CountData, the range is defined from which byte data shall be read (method Read).
Information!
This is an additional way of accessing the internal memory of the ActiveX
module. This method can
be used in programming environments which do not offer array support. Usually, the internal memory
area is accessed via the property Data, see section 3.5.14.
3.4.6 setData
Description
Writing access to the internal memory area of the ActiveX
module, in which the data to
be written of the method Write are stored.
Syntax
object.setData (short Bytelndex, short DataValue);
Comments
With the method setData, the internal memory area of the ActiveX
module can be
written. Upon triggering the event OnWrite, the data are written from the temporary
storage to the key. In the properties StartAdress and CountData, the range is defined
from which byte data shall be written (method Write).
Information!
This is an additional way of accessing the internal memory of the ActiveX
module. This method can
be used in programming environments which do not offer array support. Usually, the internal memory
area is accessed via the property Data, see section 3.5.14.
098655-03-10/12