beautypg.com

Bunn VPS User Manual

Page 5

background image

Page 5

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

This brewer is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices

PROBLEM

Water is not hot

Spitting or excessive steaming

PROBABLE CAUSE

1. Limit Thermostat or Thermal
Cut-Off
CAUTION - Do not eliminate or
bypass limit thermostat/thermal
cut-off. Use only BOM replace-
ment part.
Limit Thermostat - #29329.7000

2. Control Thermostat

3. Tank Heater

1. Lime Build-up
CAUTION - Tank and tank
components should be delimed
regularly depending on local
water conditions. Excessive
mineral build-up on stainless
steel surfaces can initiate corro-
sive reactions resulting in
serious leaks.

2. Control Thermostat

REMEDY

Refer to

Service

- Limit Thermo-

stat or Thermal Cut-Off for
testing procedures. See page 10
or 13

Refer to

Service

- Control Ther-

mostat for testing procedures.
See page 9

Refer to

Service

- Tank Heater

for testing procedures. See page
12

Inspect the tank assembly for
excessive lime deposits. Delime
as required.

Refer to

Service

- Control Ther-

mostat for testing procedures.
See page 9

10053 022300

This manual is related to the following products: