Enerpac BRP-302 User Manual
Page 3
SPECIFICATIONS
Model
No.
Capacity
Tons
Stroke
in (cm)
Effective
Area
in
2
(cm
2
)
Oil
Capacity
in
3
(cm
3
)
Weight
lbs (kg)
A
in.
(cm.)
B
in.
(cm.)
C
in.
(cm.)
BRP106C
10
6.00
(15,24)
2.32
(15,0)
13.8
(226,2)
35
(15,9)
23.13
(58,75)
--
1.38
(3,51)
BRP106L
10
6.00
(15,24)
2.32
(15,0)
13.8
(226,2)
29
(13,2)
22.19
(56,36)
28.19
(71,60)
1.18
(3,00)
BRP302
30
2.50
(6,35)
7.22
(46,6)
18.5
(303,2)
75
(34,0)
36.00
(91,44)
43.57
(110,7)
1.50
(3,81)
BRP306
30
6.00
(15,24)
7.22
(46,6)
43.3
(709,7)
106
(48,1)
37.95
(96,4)
43.95
(111,6)
1.50
(3,81)
INSTALLATION
Attach hose to coupler in
3
/
8
" NPT port. Connect mating coupler halves together hand
tight only. Using tools will damage the coupler.
CAUTION
Position hoses to avoid sharp bends, kinks, and sharp impacts from
falling objects, because they may cause wear or damage to the hose,
leading to premature failure.
OPERATION
Refer to the instruction sheet supplied with your pump for information on installing and
operating your pump.
1.
Check the oil level in the pump.
2.
Make sure all connections are tight and leak free.
3.
Remove air from the system by placing the cylinder at a lower level than the pump
with the coupler facing up. Cycle the cylinder several times until the motion is
smooth.
. . . continued . . .
A
C
B
3
/8" NPT
BRP-302, BRP-306
3
/8" NPT
A
C
B
BRP-106C
3
/8" NPT
A
B
C
BRP-106L
3