ALCOVE INSTALLATION
CAUTION:
READ ENTIRE MANUAL BEFORE INSTALLING HEATER.
1. For clearances, see Figure 3. The minimum clearances must be met.
2. For “Installation and Gas Connection”, see page 17.
FOR YOUR SAFETY:
WHAT TO DO IF YOU SMELL GAS
-Do not try to light appliance.
-Do not touch any electrical switch.
-Do not use telephone in building.
-Call your gas supplier immediately, from a neighbor’s phone. Follow the gas supplier
instructions.
-If you cannot reach your gas supplier, call the Fire Department.
-Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of
this appliance or any other appliance.
WARNING:
DO NOT USE THIS ROOM HEATER IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE ROOM HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM
AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE, OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST BE PERFORMED
BY A QULIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
“WARNING:
ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE
DANGEROUS.”
NOTE: The depth of the alcove must allow a 4" minimum clearance at the rear. The width of
the alcove must allow a 5” clearance on the right side and the left side. The height of the alcove
must allow for a 10” clearance form the top of the heater to the ceiling of the alcove. The front
edge of the heater must meet the front of the alcove, and have a minimum of 24” to any
combustible material.
NOTE:
DIMENSIONS SHOWN ARE
MINIMUM CLEARANCE TO
COMBUSTIBLE WALL.
FLOOR
PROTECTOR
4"
5"
WALL
STOVE
10"
Figure 3