SUPPLEMENTARY INSTRUCTIONS FOR SAFE
USE (NORMAL OPERATION WITH NO
OPERATOR INTERVENTION)
10.1
Keep Enclosures Closed During Use
10.1.1
Transmitter
Verify the following:
The transmitter cover should be tightly closed and all 4 screws
installed to secure the cover.
Cable glands should be properly installed and snug in their
mounting holes in the enclosure and snug around their cables.
Cables shall be prevented from applying pulling or twisting
forces on the cable glands.
10.1.2
Sensor Head
Verify the following:
All sensor head latches should be snugly mated.
Clamps should be snugly installed on the boot seals.
The cable connector shall be snugly latched onto the mating
connector.
The cable shall be installed with a drip loop (if necessary) such
that water will not run along the cable toward the connector
The cable shall be installed such that the connector will not be
subjected to twisting or pulling forces.
10.2
Periodic Inspections
Include the sonar process monitoring system in periodic inspections of
the facility.
10.2.1
Transmitter Inspections
Verify the absence of the following:
Loose hardware or fittings
Damage to enclosure
Damage to seals
Dirt or moisture inside enclosure
20909-01C Rev 04
Page 10-1