5
Installation
Plumbing Connections
Installation
1.
Connect compression fittings from the cold water supply line located
at the base of the dishwasher booster heater to the HRU.
2.
Connect compression fittings from the HRU return line at the rear
of the HRU to the booster inlet located at the base of the machine.
3.
Connect the red drain hose from the base of the HRU to the
fitting on the rear drain line of the dishwasher. The fitting is located
directly below the HRU drain line.
Refer to the photograph below and follow the instructions to connect the
water lines to the HRU.
COLD WATER
IN
HRU WATER
OUT
HRU DRAIN
OUT
Heat Recovery Unit (HRU) water and drain lines are connected at the rear of the dishwasher.