Carter-Hoffmann MC243S-2T User Manual
Page 4

4
IMPORTANT:
Front and back of cabinet
must remain clear for
access.
Maintain 2” of clearance
on each side of cabinet to
allow for adequate cooling.
NOTE:
The technical con-
tent of this manual, includ-
ing any wiring diagrams,
schematics, parts break-
down illustrations and/or
adjustment procedures, is
intended for use ONLY by
qualified technical per-
sonnel
.
MODEL
MODULES
WATTS
VOLTS
AMPS
MC1W1H
1
200
120
1.7
MC1W2H
2
400
120
3.3
MC1W3H
3
600
120
5.0
MC1W4H
4
800
120
6.7
MC1W5H
5
1000
120
8.3
MC2W1H
2
400
120
3.3
MC2W2H
4
800
120
6.7
MC2W3H
6
1200
120
10.0
MC3W1H
3
600
120
5.0
MC3W2H
6
1200
120
10.0
MC4W2H
8
1600
120
13.3
MC2W4H
8
1600
120
13.3
ELECTRICAL SPECIFICATIONS
1. Check for proper voltage and circuit breaker size. Cabinet requires 120
volt, single phase, 15 Amp circuit. Refer to serial tag on the cabinet for the
electrical requirements for your particular cabinet.
2. Ensure receptacle is correctly installed and operating safely. Requires
grounded NEMA 5-15R receptacle.
3. Position cabinet on table or counter top. Maintain 2” of clearance on each
side to allow for adequate cooling.
Location
For proper operation and maximum performance, locate the unit in an ambient
air temperature of less than 80°F (21°C).
Avoid areas near exhaust fans where there are active air movements.
For safe operation, locate the unit a reasonable distance from combustible
walls and materials.
To prevent injury and damage, locate the unit at a proper and safe working
height. The location should be level, clean of debris, and strong enough to
support the weight of a fully loaded unit.
Counter-top Mounting
To prevent electrical shock, be sure unit is unplugged from an electrical outlet.
If unit has been operated, allow unit to cool before installing. For safety
reasons, countertop must be made of a non-combustible material, clean and
free of debris.
MODEL
MODULES
WATTS
VOLTS
AMPS
MC123
3
900
120
7.5
MC125
5
1500
120
12.5
MC112S-2
1
300
120
2.5
MC112S-4
1
300
120
2.5
MC112S-6
1
300
120
2.5
MC212S-2
2
600
120
5.0
MC212S-4
2
600
120
5.0
MC212S-6
2
600
120
5.0
MC212S2-2DD
2
600
120
5.0
The charts below give electrical specifications for the most popular models, but due to the nature of
continuing change to the number of configurations we manufacture, may not list your model. Refer
to the serial tag on your cabinet for actual electrical specifications.
INSTALLATION AND START-UP
Sample serial tag
location of electrical specs
GROUND
PIN
NEMA 5-15P
PLUG
NEMA 5-15P
RECEPTACLE