beautypg.com

Bakers Pride FC-816 Manual User Manual

Page 9

background image

'

d) The hot surface ignition system, all related switches, indicator light and fuse, are all connected through

the 6 ft (1830 mm) power supply cord. The power supply cord must be plugged into a properly grounded

three-prong receptacle.

e) A wiring diagram may be found behind the service panel on the left side of the unit and also in this

manual.

f) The ovens should not be installed on the same line with space heaters, boilers or other gas equipment

with high intermittent demand.

g) Use a pipe joint compound that is resistant to the action of liquefied petroleum gases when making gas

connections.

h) For Propane gas, use a least ½” pipe or tubing with a 5/8” inside diameter. For Natural gas, use ¾” pipe.

i) The appliance must be isolated from the gas supply piping system by closing its manual shut-off valve

during any pressure testing of the gas supply piping system at test pressures equal to or less than ½” psig

(3.45 kpa).

j) The appliance and its shut-off valve must be disconnected from the gas supply piping system during any

pressure testing of that system at test pressures in excess of ½” psig (3.45 kpa).

k) The gas pressure regulators are part of the combination valves and are adjusted to yield a pressure of

3.5” water column (9 mbar) for Natural Gas. If the oven has been ordered for use on Propane Gas, the

pressure regulators in the combination valves are preset at the factor to yield a pressure of 10” water

column (25 mbar).

l) A separate shut-off valve for each oven must be provided. It should be as close as possible to the place

where the gas line enters the oven. It must be located where it is easily and quickly accessible.

m) When stacking with another type of oven, two (2) shut-off valves, one for each of the two ovens, must be

provided.

After the gas supply has been connected, it is extremely important to check all the piping for leaks. Use a

soap and water solution or a product made expressly for this purpose. Do not use matches, candles or a

flame etc. to check leaks since these methods are extremely dangerous.

The purpose of the safety pilot system is to lock the gas supply to the burner at the combination valve, if for

any reason the pilot burner is not lit. The pilot should be re-lighted by following the steps given below.

However, in normal service, the pilot flame stays lit indefinitely, day and night, including weekends. This

prolongs the life of the safety valve.

Do not cut or remove the ground prong from the plug.

7. SAFETY PILOT OPERATION:

The safety pilot valve is in effect a two-stage control. After initial lighting, the pilot burner stays on without

the gas cock dial being held pressed in. After 1-2 minutes, the valve opens fully to let the gas flow past the

safety pilot valve and into the burner system.

A) Partially depress and turn the gas cock dial to the “OFF” position.

b) Wait for five minutes to allow gas, which may have accumulated in the burner compartment, to escape.

c) Turn gas cock dial to “PILOT” position.

d) Depress gas cock dial.

e)

With a match or igniter light pilot burner. Hold gas cock dial in pressed position for

about 1/2” minute and then release it. The Pilot Burner flame should now remain lit.If Pilot Burner fails to

ignite or does not remain lit, repeat steps (a) thru e).

f)

Flip toggle switch to the “ON” (I) position. The amber indicator lamp will light up and

the igniter will be energized and start to glow. Hold gas cock dial in pressed position for about 2-3 minutes

and then release it. The Pilot Burner flame should now remain lit. If Pilot Burner fails to ignite or does not

remain lit, repeat steps (a) thru (d) and (f).

The built-in igniter is for convenience of lighting only and not necessary for the booster burner

operation. In case of power failure, or if the igniter will not light the pilot flame, the pilot flame can also be lit

with a long hand-held igniter or with a long, lit taper.

It is important to have the correct Pilot Burner Flame size as shown in (Sketch “J”). If necessary, adjust the

Pilot Burner Flame by turning the Pilot Adjustment Screw (see Sketch “K”) clockwise to reduce or counter-

clockwise to increase.

A. PILOT BURNER LIGHTING PROCEDURE:

For Main Burner:

For Booster Burner:

Note:

B. PILOT BURNER FLAMEADJUSTMENT: