General maintenance, Danger – Autoquip TITAN UPENDER User Manual
Page 21
21
15. Restore the oil level.
16. Fully tilt the Upender and hold the “TILT RETURN” button for 45 – 60 seconds to
allow air in the lines to bleed back into the tank.
17. Cycle the Upender 10 – 15 times.
18. Check the oil level.
19. Clean the oil fill breather cap.
20. Clean up any debris and/or spilled oil from the area.
NOTE: Depending on experience, the job should take 1 – 2 hours.
PIPE THREAD SEALANT
Loctite PST #567 pipe thread sealant or equivalent is recommended. Do not use
Teflon tape. Tape fragments can cause malfunctioning of the hydraulic system.
VELOCITY FUSE REPLACEMENT
DANGER
!
Do not attempt to remove the velocity fuse until the hydraulic pressure has
been removed from the lifting cylinders and hydraulic hoses. Failure to
follow these instructions could result in personal injury or death!
Never attempt to take a velocity fuse apart and repair it. These are precision devices
that are factory assembled under exacting conditions. Velocity fuses should always be
replaced.
1. The arrow on the exterior surface of the velocity fuse shows the direction of the
restriction to the oil flow. The arrow should always point away from the cylinder.
2. Do not use Teflon tape on the threaded connections of a velocity fuse. Tape
fragments can cause malfunctioning of the fuse.
3. Check all fitting connections for hydraulic leaks and tighten as necessary.
GENERAL MAINTENANCE