4. Make temporary electrical connections and permanent hydraulic connections. Raise
the Upender approximately one foot using the “TILT” button. Then tilt it fully, holding
the “TILT RETURN” button for approximately 60 seconds. Repeat this process five
to seven times to bleed any air out of the hydraulic system, alternating directions
each time.
.
5. Raise and lower the Upender to make positioning adjustments and align the platform
in the pit with a proper clearance of _” minimum around the edges from the platform
to the pit angle.
DANGER
!
To avoid personal injury, NEVER go under the Upender platform until the
load is removed and the platform is securely blocked in position.
6. Make the permanent electrical connections and operate the Upender through a few
cycles.
CLEAN UP
1. Clean up any debris from the area. A clean installation makes a good impression
and creates a much safer environment!
2. Touch-up paint is available from Autoquip for repair of damaged paint surfaces.
WARNING!
All
DANGER,WARNING, and CAUTION labels and
informational decals and plates must be intact and in place on the Upender.
Contact an Autoquip representative if labels are missing or damaged. See
“DANGERS, WARNINGS, and CAUTIONS” section of this manual.
INSTALLATION INSTRUCTIONS