Interlock installation (cont.) – Autoquip GATES SLIDING User Manual
Page 13
12
___________________________________________________________
2. Make sure that the solenoid is secure in the set collar, being seated fully against the shoulder of the
bracket.
DO NOT OVERTIGHTEN
(OVERTIGHTENING SET SCREW WILL INHIBIT BOLT OPERATION)
3. All gates will require the installation of a gate status switch. The purpose of this switch is to “prove”
that the gate is closed and in a position to accept the interlock bolt in the striker.
4. Single panel gates require a single switch located on the gate post.
5. Adjust the interlock and the strike so that the interlock bolt is fully seated in the strike
NOTE: The locking bolt has a throw of 1/2”. Make sure that it is fully engaged after adjustment.
6. Install the cover plate to the mounting plate with 10-32 x 1/4 THS which are supplied.
7. Adjust the gate status limit switch(s) so that the lift will not operate if the gate is opened more than
1”.
INTERLOCK INSTALLATION (Cont.)
___________________________________________________________