beautypg.com

Lf miniature liquid level sensors – APG LF Series datasheet User Manual

Page 2

background image

3

Automation Products Group, Inc.
1025 West 1700 North

Tel. 1/888/525-7300

Logan, UT 84321 USA

Fax 1/435/753-7490

w w w . a p g s e n s o r s . c o m

s a l e s @ a p g s e n s o r s . c o m

LF Miniature Liquid Level Sensors

APG

Automation Products Group, Inc.

®

Protection from Electrical
Surges

Overvoltage

Reed switches are not designed for

the direct starting of inductive loads

such as motors, contactors, solenoid

valves, etc. They are susceptible

to damage from overvoltages. Do

not exceed the specified switch

ratings listed in the specifications

charts. Contactors should be wired

to miniature relays, suppressors or

similar devices. APG recommends

the use of the relay unit, Model

RCU-7000. (Complete RCU-7000

specifications are located at www.

apgsensors.com)

Overcurrent

Momentary surge currents

produced by switching lamps or

stray capacity from long cable

lengths can weld the reed switches.

Contactors should be wired to our

Model RCU-7000 relay unit, coils

in series, or suppressors. (Complete

RCU-7000 specifications are located

at www.apgsensors.com)

Intrinsic Safety

Any of the APG float switch level

controls may be used with APG

Intrinsic Safety Barriers (IS) to meet

hazardous location requirements

for level control device. For more

information see www.apgsensors.

com

Ordering Information

Please order by part number, as

shown on the specification charts on

the following pages.

Technical Notes

The sealing compound over

the lead wire egress prevents

moisture penetration, but is

insufficient to prevent water

penetration. Please install in an

appropriate location or apply a

suitable sealant.

If there is surface wave motion,

use a time delay relay to dampen

the switch action.

The switch should be located

away from strong magnetic fields

such as those produced by motors

or solenoid valves.

Maximum allowable impact is 10

g. Shocks greater than this can

damage the switch.

Maximum tensile force on the

lead wire is 4.4 lb. (19.6 N)

Exceeding this during installation

may damage the switch.

Wiring

White

(yellow)

Black

(yellow)

Switch

Switch Rating

See specification charts on the

following pages.

Submersibility

These miniature liquid level

switches are not designed to operate

when fully submersed. The LFS-

VE-S1 and LFS-VE-S2 series float

switches can be submersed for

short periods up to 76 hours under

500 mm depth of water at 20°C

temperature. Water will penetrate

the float for elevated temperatures

and/or greater depths.