Starting cold engine, Ower, Runer – Echo PPT-280 Serial E08612001001 - E08612005941 User Manual
Page 19: Perator, Anual
P
ower
P
runer
TM
o
PeraTor
'
s
M
anual
19
startIng
cold
engIne
WARNING
The attachment will operate immediately when the engine starts
and could result in loss of control and possible serious injury. Keep
movable parts of the attachment off the ground and away from
objects that could become entangled or thrown.
1. Stop Switch
Move stop switch button (A) forward away from the STOP
position.
2. Choke
Move choke (B) to “Cold Start” (
) Position.
3. Purge Bulb
Pump purge bulb (C) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4. Recoil Starter
Lay the unit on a flat, clear area, and keep movable attachment
parts clear of all obstacles. Firmly grasp throttle handle and throttle
trigger lockout with left hand and fully depress throttle trigger to
wide open position. Rapidly pull recoil starter handle/rope (D)
until engine fires (or maximum five [5] pulls).
5. Choke
After engine fires (or five [5] pulls), move choke lever back to
“Run” (
) position. Hold throttle trigger and throttle trigger
lockout fully depressed and pull recoil starter handle/rope until en-
gine starts and runs. Release throttle trigger and allow unit to warm
up at idle for several minutes.
NOTE
If engine does not start with choke in “Run” position after 5 pulls,
repeat instructions 2 - 5.
6. After engine warms up, gradually depress throttle trigger to in-
crease engine RPM to operating speed.
A
C
D
B