10 discharge tube, 11 switch box, 10 discharge tube 2.11 switch box – Echo CH8670H Owners Manual v.2 User Manual
Page 12
8
TURNTABLE CHIPPER
ASSEMBLY
coNNEcTING ThE SWITch boX
Connect the Relay Input plugs to the Proximity
1.
sensors.
Relay Input Plug (Forward): Red/green/White wires.
•
Relay Input Plug (Reverse): Red/Orange/White
•
wires.
Forward/Reverse Sensors: Blue/Black/Brown wires.
•
The forward/reverse sensors have the same color
wires. use the steps below to verify that they are
properly connected to the Relay Input Plugs:
start engine.
•
Move the Control Bar to the REVERSE position.
•
If the feed roller does not rotate in reverse direction,
•
shut off engine and switch the forward & reverse
signal plugs.
The remaining connectors can be connected by
2.
matching the colored wires.
SETTING ThE SWITch boX SENSoRS opERaTING dISTaNcE
remove the switch box cover.
1.
Verify that the sensors are within 2mm (5/64") from
2.
the switch box plate and adjust if needed.
2.11 SWITch boX
2.10 dISchaRGE TubE
Attach the discharge tube to the mounting flange on the
1.
chipper frame. Half of the mounting clamp is already
attached to the tube. Slide the tube onto the flange
and tighten the bolts to secure it.
Install the second half of the clamp to the tube and
2.
flange.
grease the zerk and tighten the nuts completely.
3.
loosen each nut one turn and attempt to rotate the
4.
tube. If it does not rotate freely, loosen each nut 1/2
turn until it rotates freely.
rotate the tube 360 degrees and lock it in place with
5.
the handle to make sure it is mounted correctly.
keep nuts as tight as possible while allowing the
discharge tube to freely turn.
NoTE
SECOND
HALF OF CLAMP
ZERK
Figure 2.3 - Discharge Tube Assembly
Figure 2.5- Switch Box Sensors.
Figure 2.4- Switch Box Connectors.