beautypg.com

Installing the solenoid cartridge valve, Installing the sensor, Positioning the sensor – Echo CH9540H Instruction v.1 User Manual

Page 2: Electrical installation

background image

Instruction Sheet

Figure 3

InSTaLLIng ThE SOLEnOID

CaRTRIDgE VaLVE

remove outer plug (using 5/16" allen wrench) from the

1.

top of the valve manifold.
once the outer plug has been removed, using a 3/16

2.

allen wrench, extract the inner plug located in the relief

valve (Figure 3).

InSTaLLIng ThE SEnSOR

Secure the sensor bracket with the lower left bearing

1.

bolt and position it (the sensor) so it aligns with the set

bolt (Figure 5).

POSITIOnIng ThE SEnSOR

Position the sensor approximately 1/16” - 1/8” from the

1.

head of the bolt (Figure 6).
replace the belt guard weldment using 5/16” hard-

2.

ware.

ELECTRICaL InSTaLLaTIOn

Attach the chipper to the tractor. connect the rEd

1.

positive lead to a +12 volt dc power source on the

tractor.

connect the BlAcK negative lead to a grounding

2.

source on the tractor.

drill a 3/16" hole in the Pto stand, close to the

3.

solenoid valve, and secure the ground wire with the #10

self-tapping screw provided.

connect the two-pin connector to the top of the valve

4.

coil.

connect the socket connector to the loFA control.

5.

Secure the wiring harness with cable ties as appropriate.

6.

Figure 5

Figure 6

SENSOR

BOLT, 1/2 X 2 HEX

SENSOR BRACKET

NUT, 1/2 CENTERLOCK

1/8" - 1/16"

GAP

Figure 3, 3/16" inner plug

replace the removed components with the new sole-

3.

noid cartridge valve and coil.
connect solenoid wiring to loFA control wiring har-

4.

ness (Figure 4).