22 machine configuration programming information – JLG 260MRT ANSI Service Manual User Manual
Page 63

SECTION 2 - PROCEDURES
3121108
– JLG Lift –
2-41
2.22 MACHINE CONFIGURATION
PROGRAMMING INFORMATION
TABLE 2-12 APPLIES TO MACHINES WITH 4170010 SOFTWARE.
NOTE: When configuring a MRT scissors machine, the
machine configuration must be completed before
any personality settings can be changed. Changing
the personality settings first and then changing the
model number of the machine configuration will
cause the personality settings to return to default val-
ues.
Table 2-12. Machine Configuration Programming Information - 4170010 Software
CONFIGURATION
DIGIT
NUMBER
DESCRIPTION
DEFAULT
NUMBER
1
(Model #)
0
260 MRT
0
2
(Engine Selection)
0
1
750 Dual Fuel
905 Diesel
0
3
(Tilt Config)
0
1
2
CE W/O Cutout - Default setting for CE machines. Tilt angle is 3° side to side
and 5° front to back.
DOM/CSA W/CUT - Cutout lift up and drive if tilted and elevated. Required
for CSA market. Tilt angle is 3° side to side and front to back.
LIFTup and DRIVE - Cutout lift up and drive if tilted and elevated. Required
for AUS and BRZ markets. Optional for DOM and CE markets. TIlt angle is
3° side to side and 5° front to back.
1
4
(Drive Cutout)
0
1
No drive cutout switch installed.
Cuts out drive when deck is elevated above a predetermined elevation
(Not available on 260MRT)
0
5
(Control Direction)
0
1
FWD & LIFT up
FWD & LIFT down (for future use)
0
6
(Leveling Jacks)
0
1
No
Yes
0
7
(Axle Type)
0
1
2
DOM and CE FIXED
DOMESTIC OSCILLATING
CE OSCILLATING
0
8
(Function Cutout)
0
1
2
NONE
DRIVE and LIFT UP
ALL FUNCTIONS
0
9
(Load)
0
1
2
NOT INSTALLED
CUTOUT PLATFORM
CUTOUT ALL
0