SECTION 4 - BOOM & PLATFORM
3121160
– JLG Lift –
4-51
Calibration - ADE Equipped Machines
1. Connect the JLG Hand-held analyzer to the original
analyzer connection in the ground box.
DO NOT CONNECT TO THE ANALYZER CONNECTION PORT
INSTALLED WITH THE UPRIGHT MONITORING SYSTEM MODULE.
2. Pull out the emergency stop button at the ground
control station and start the engine from the ground
controls.
3. To calibrate the Upright Monitoring System through
the hand-held analyzer, you must be in access level
1. To advance to access level 1, scroll to the
ACCESS LEVEL menu and press "ENTER"
.
Using the arrows on the keypad, enter the password
"33271" and press "ENTER"
.
4. Calibrate the upright monitoring system sensor by
the following procedure:
a. In access level 1, scroll through the menu items
until "CALIBRATIONS" is displayed on the sec-
ond line of the analyzer screen. The screen will
display the following:
b. After pressing 'ENTER"
one of the following
screens will be displayed:
Or:
c. Scroll left to right through the above menu items
until "UMS SENSOR" sub menu appears on the
bottom line of the analyzer display. Press the
"ENTER"
key.