Torque requirements, Hydraulic oil, Torque requirements -9 hydraulic oil -9 – JLG 600A_AJ Operator Manual User Manual
Page 109: Torque requirements -9, Hydraulic oil specifications -9, Torque requirements hydraulic oil

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
3121204
– JLG Lift –
6-9
Torque Requirements
Hydraulic Oil
NOTE:
Hydraulic oils must have anti-wear qualities at least to API
Service Classification GL-3, and sufficient chemical stabil-
ity for mobile hydraulic system service. JLG Industries
recommends Mobilfluid 424 hydraulic oil, which has an
SAE viscosity index of 152.
NOTE:
When temperatures remain below 20° F (-7° C), JLG
Industries recommends the use of Mobil DTE 13M.
Table 6-13. Torque Requirements
Description
Torque Value (Dry)
Interval
Hours
Bearing To Chassis
See Note
50/600*
Bearing To Turntable
See Note
50/600*
Wire Rope
15 ft. lbs (20 Nm)
150
Wheel Lugs
150
Engine Mounting Bolts
165 ft. lbs. (231 Nm)
A/R
Engine Manifold Mounting Bolts
30 ft. lbs. (42 Nm)
A/R
*Check swing bearing bolts for security after first 50 hours of operation and
every 600 hours thereafter. (See Swing Bearing in Section 3.)
Table 6-14. Hydraulic Oil Specifications
HYDRAULIC SYSTEM OPERATING
TEMPERATURE RANGE
SAE VISCOSITY
GRADE
+0° to +180° F (-18° C to +83° C)
10W
+0° F to +210° F (-18° C to +99° C)
10W-20, 10W-30
+50° F to +210° F (+10° C to +210° C)
20W-20