SECTION 3 - MACHINE CONTROLS AND INDICATORS
3-16
– JLG Lift –
3121138
1. Level System Fault Indicator
Indicates a fault in the electronic leveling system. The
fault indicator will flash and an alarm sound. All func-
tions will default to creep if the boom is extended more
than 20 inches (51 cm) or elevated above horizontal.
IF THE LEVEL SYSTEM FAULT INDICATOR IS ILLUMINATED, SHUT
DOWN THE MACHINE, RECYCLE THE EMERGENCY STOP, AND RESTART
THE MACHINE. IF THE FAULT PERSISTS, RETURN THE PLATFORM TO
THE STOWED POSITION, USING MANUAL LEVELING AS REQUIRED,
AND HAVE LEVELING SYSTEM REPAIRED.
2. AC Generator (Green)
Indicates the generator is in operation.
3. Overload Indicator. (If equipped)
Indicates the platform has been overloaded.
4. Capacity Indicator
Indicates the maximum platform capacity for the current
position of the platform. Restricted capacities are permit-
ted at restricted platform positions (shorter boom
lengths and higher boom angles).
NOTE: Refer to the capacity decals on the machine for restricted
and unrestricted platform capacities.
5. Tilt Alarm Warning Light and Alarm
This orange illuminator indicates that the chassis is on a
slope. An alarm will also sound when the chassis is on a
slope and the boom is above horizontal. If lit when boom
is raised or extended, retract and lower to below hori-
zontal then reposition machine so that it is level before
continuing operation. If the boom is above horizontal
and the machine is on a slope, the tilt alarm warning
light will illuminate and an alarm will sound and CREEP
is automatically activated.
IF TILT WARNING LIGHT IS ILLUMINATED WHEN BOOM IS RAISED OR
EXTENDED, RETRACT AND LOWER TO BELOW HORIZONTAL THEN
REPOSITION MACHINE SO THAT IT IS LEVEL BEFORE EXTENDING
BOOM OR RAISING BOOM ABOVE HORIZONTAL.