JLG 660SJ Service Manual User Manual
Page 264

SECTION 6 - JLG CONTROL SYSTEM
6-18
– JLG Lift –
3121298
Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions
Fault Flash
Code
Communicated (Displayed on
Analyzer) Fault
Description
Priority
None
No flash code is indicated for the following help messages. They are intended to
hint at a possible problem if vehicle is not behaving as expected.
1
EVERYTHING OK
The “normal” help message in platform mode
GROUND MODE OK
The “normal” help message in ground mode
FSW OPEN
A drive or boom function has been selected but footswitch is open.
RUNNING AT CREEP – CREEP
SWITCH OPEN
All function speeds are limited to creep because creep switch is open.
RUNNING AT CREEP – TILTED
AND ABOVE ELEVATION
All boom function speeds are limited to creep because vehicle is tilted and
above elevation.
RUNNING AT CUTBACK – ABOVE
ELEVATION
Drive speed is limited to “ELEVATED MAX” because vehicle is above elevation.
TILT SENSOR OUT OF RANGE
The tilt sensor has indicated a tilt angle greater than 19 degrees for more than 4
seconds. Not reported during 2 second power-up.
LOAD SENSOR READING UNDER
WEIGHT
The load sensor is reading 20% or more under the calibrated zero point. This
fault may occur if platform is resting on the ground. Not reported during 2 sec-
ond power-up.
1/1
Flash code 1/1 indicates a “sleep” mode.
NOT REQUIRED
2/1
Flash code 2/1 indicates problems with footswitch.
2
FSW FAULTY
The two footswitch inputs have read the same state for more than one second.
KEYSWITCH FAULTY
Both platform and ground modes are selected simultaneously
2/2
Flash code 2/2 indicates problems with drive & steer selection. Except where
noted, these faults are not reported during 2 second power-up sequence.
3
DRIVE LOCKED – JOYSTICK
MOVED BEFORE FOOTSWITCH
Drive was selected before and during footswitch closure. Can be reported dur-
ing power-up sequence.
FSW INTERLOCK TRIPPED
Footswitch was closed for seven seconds with no function selected. Can be
reported during power-up sequence.
STEER LOCKED – SELECTED
BEFORE FOOTSWITCH
Steer was selected before and during footswitch closure.
STEER SWITCHES FAULTY
Both steer switches are active together.
DRIVE / STEER WITH NO QPROX
This fault only occurs with inductive joysticks. It occurs if the joystick is moved
out of the neutral position with no Qprox sensors active.
D/S JOY. QPROX BAD
These faults only occur with inductive joysticks. They indicate that the Q-Prox
sensor is reading above 3.18 volts.
D/S JOY. OUT OF RANGE LOW
Resistive joysticks: These faults do not occur.
Inductive joysticks: The trigger points for these faults are dependent on the
centertap voltage reading. These faults will be triggered when the voltage is
less than the centertap voltage minus half the center tap voltage minus 0.3
volts. If the centertap is at the high end of the range, these faults will be trig-
gered below 1.05 volts. If the centertap is at the low end of the range, these
faults will be triggered below 0.79 volts.