2 machine personality settings, Machine personality settings -15, Personality ranges/defaults -15 – JLG 660SJ Service Manual User Manual
Page 261

SECTION 6 - JLG CONTROL SYSTEM
3121298
– JLG Lift –
6-15
6.2 MACHINE PERSONALITY SETTINGS
NOTE:
Personality settings can be adjusted within the adjustment
range for optimum machine performance.
Table 6-2. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS - 600S
DRIVE
ACCELeration
0.1s to 5.0s
2.0
DECELeration
0.1s to 3.0s
2.0
Forward MINimum speed
0 to 35%
4
Forward MAXimum speed
0 to 100%
35
REVerse MINimum speed
0 to 35%
4
REVerse MAXimum speed
0 to 100%
35
ELEVATED MAXimum speed
0 to 50%
15
CREEP MAXimum speed
0 to 50%
25
Engine RPM
800 to 2900
1800
TOWER LIFT
ACCELeration
0.1 to 5.0
N/A
DECELeration
0.1 to 3.0
N/A
MlNimum UP speed
0 to 60%
N/A
MAXimum UP speed
0 to 100%
N/A
MINimum DOWN speed
0 to 60%
N/A
MAXimum DOWN speed
0 to 100%
N/A
Engine RPM
800 to 2900
N/A
UPPER LIFT
ACCELeration
0.1 to 5.0
2.0
DECELeration
0.1 to 3.0
0.7
MlNimum UP speed
0 to 60%
40
MAXimum UP speed
0 to 100%
80
CREEP Maximum UP speed
0 to 65%
55
MINimum DOWN speed
0 to 60%
40
MAXimum DOWN speed
0 to 100%
70
CREEP maximum DOWN speed
0 to 75%
55
Engine RPM
800 to 2900
1800