beautypg.com

Sp2 specifications, Appendix b, Infra-red remote codes – Bryston SP2 PREAMP User Manual

Page 18

background image

17

Power OFF . . . . . . . . . . . .000
TV/SAT ............................001
DVD .................................002
CD ...................................003
AUX .................................004
VCR .................................005
TAPE . . . . . . . . . . . . . . . .006
Volume UP. . . . . . . . . . . .007
Volume DOWN . . . . . . . . .008
MUTE (toggle)

3

. . . . . . . .009

TEST ................................010
DIGITAL ...........................011
DOLBY. . . . . . . . . . . . . . .012
STEREO. . . . . . . . . . . . . .013
THX . . . . . . . . . . . . . . . . .014
POWER ON/OFF

3

. . . . . . .015

DTS .................................016
SURROUND . . . . . . . . . . .017
MODE . . . . . . . . . . . . . . .018
MENU UP. . . . . . . . . . . . .019
MENU DOWN. . . . . . . . . .020
SELECT . . . . . . . . . . . . . .021
CENTRE. . . . . . . . . . . . . .022
REAR. . . . . . . . . . . . . . . .023
BACK. . . . . . . . . . . . . . . .024
SUB. . . . . . . . . . . . . . . . .025
SAVE . . . . . . . . . . . . . . . .026
BYPASS 2 CH ON/OFF

3

. . .027

BYPASS 6 CH ON/OFF

3

. . .028

Power ON . . . . . . . . . . . .029
SPV-1

1

Reserved..............030

. . . . . . . . . . . . . . . . . . through
SPV-1 Reserved ...............048
OSD

2

On/Off

3

. . . . . . . . . .049

OSD Off . . . . . . . . . . . . . .050
OSD On . . . . . . . . . . . . . .051
MONO . . . . . . . . . . . . . . .052
BYPASS 2 Ch ON . . . . . . .053
BYPASS 6 Ch OFF . . . . . .054
BYPASS OFF . . . . . . . . . .055
DIGITAL ON . . . . . . . . . . .056
DIGITAL OFF . . . . . . . . . .057
MUTE ON. . . . . . . . . . . . .058
MUTE OFF . . . . . . . . . . . .059
BYPASS SUB TOGGLE

3

....060

FORCE DIGITAL ON . . . . .061
FORCE DIGITAL OFF. . . . .062

SURROUND MODES
MODE NONE . . . . . . . . . .064
PROLOGIC . . . . . . . . . . . .065
PLII MUSIC . . . . . . . . . . .066
PLII MOVIE . . . . . . . . . . .067
NEO6 MUSIC . . . . . . . . . .068
NEO6 MOVIE . . . . . . . . . .069
STEREO 5 . . . . . . . . . . . .070
PARTY . . . . . . . . . . . . . . .071
HALL . . . . . . . . . . . . . . . .072
CHURCH . . . . . . . . . . . . .073
STADIUM . . . . . . . . . . . . .074

CLUB. . . . . . . . . . . . . . . .075
THEATRE . . . . . . . . . . . . .076
NATURAL. . . . . . . . . . . . .077

Dynamic Range Scroll . . .090
Chatter Detect ON . . . . . .091
Chatter Detect OFF . . . . . .092
Restore DAE5 factory settings

7

246

Update DAE5 factory settings .247
Volume Calibration

5

. . . . .248

Turning Point

5

. . . . . . . . .249

AUTO SAVE TOGGLE

6

. . .250

Crossover Enable/Disable

3

. .251

Restore factory defaults

4

.254

NULL . . . . . . . . . . . . . . . .255

NOTES:
1) SPV-1: Bryston Video Switcher
2) OSD: On Screen Display
3) On/Off or Toggle: function is

toggled On or Off every time code
is received.

4) Use care in using this code as

ALL settings will be reset to the
factory defaults

5) For factory and service use only;

internally disabled

6) For universal remote controls

which do not have the Bryston
SP2 remote’s SAVE button, this
allows settings entered via the
remote to be saved automatically
without having to press the SAVE
button.

7) Use care in using this code as

all DAE-5 (Digital Audio Engine
or DSP module) settings will be
reset to the factory defaults

SP2 SPECIFICATIONS

I

NPUTS

Analog AudIo:

Six stereo (RCA) pairs, One 5.1 channel (RCA) input

Digital:

4 coaxial (RCA) 75 Ohms, 2 Optical (TOSLINK?), conforms to

SPDIF standard.

Pro version 1 AES/EBU input (XLR) 110 Ohms

Infrared:

1 mini (1/8”) phone jack

RS-232:

D9 connector (bidirectional)

OUTPUTS

Analog Outputs:

Left, Centre, Right, Right Surround, Left Surround, and

Subwoofer on 6 unbalanced

(RCA) and 6 balanced (XLR).

2 stereo (RCA) pairs of Record Outputs.

1 pair (RCA) Surround Back outputs

Trigger:

One 12V on/off trigger, One 12V programmable trigger, to

source 80mA total.

Serial Data:

(for video switcher): 1 mini (1/8”) phone jack

INFRA-RED REMOTE CONTROL

Number of buttons

30

Power Source

two AAA batteries

PERFORMANCE SPECIFICATIONS

A/D Conversion:

24-Bit, 48kHz Delta-Sigma

D/A Conversion:

24-Bit, up to 96kHz Delta-Sigma

DSP Engine:

TI Aureus

Power Supply:

Dual, Linear, Toroidal

Frequency Response: 20Hz to 20kHz +/- 0.25 dB

THD+Noise:

Less than 0.006% in DSP modes; Less than 0.0025% in

Bypass mode 20Hz to 20kHz at maximum output level.

Signal-to-Noise Ratio: 105dB in DSP Modes; 110dB in 2ch Bypass Mode ; 22kHz

bandwidth, Ref. 1kHz at maximum output level

Input Level:

2 Vrms in DSP modes; 4 Vrms in Bypass Mode

Input Impedance:

50kOhms

Output Level:

8 Vrms (16 Vrms Balanced) in DSP Modes; 10 Vrms (20

Vrms Balanced) in Bypass Mode.

Output Impedance: 110 Ohms

Bass Management: 2nd Order HP filter(x5), 4th Order LP filter 40 – 200 Hz Cross-

over Freq.

PHYSICAL SPECIFICATIONS

Power Requirements 100VAC, 115VAC, and 230VAC models. 200 VA. IEC detach-

able power cord (included)

Dimensions:

17” W x 13.5” D x 3.8” H; rackmount 19” W x 13.5” D x 3.5” H

Weight:

approx 22 lbs (10 kg)

Chassis Temp:

50 deg Celsius max.

Specifications subject to change without notice.

APPENDIX B:

INFRA-RED REMOTE CODES