Operating instructions, Installation – Bosch PCH 615 DAU User Manual
Page 6
6
This installation must conform with the following:
•
Manufacturer’s Installation instructions
•
Local Gas Fitting Regulations
•
Municipal Building Codes,
•
AGA Installation Code for Gas Burning Appli-
ances. (AS 5601/AG 601)
•
S.A.A. Wiring Code
•
Local Electrical Regulations
•
Any other statutory regulations
These built-in hobs are intended to be inserted in a
benchtop cutout.
Only an authorised person should connect the appli-
ance.
Installation dimensions are shown in Fig.1
Before connecting the unit, check whether the local
connection conditions (type of gas) are compatible
with the unit’s settings. Observe any special condi-
tions imposed by local suppliers (utilities). The specifi-
cations of this cooktop are stated on the data label
located on the bottom of the cooktop base.
Installation
1
11
Depress control knob and turn anti-clockwise to ‘High
flame’ position. Hold the knob down for a few sec-
onds until the flame ignites. Keep control knob de-
pressed for a few seconds to activate the flame failure
device. If ignition fails, depress knob again and wait
for ignition. Turn anti-clockwise to set the flame to the
desired intensity.
All burners are fitted with a flame failure device which
shuts off the gas supply if the flame extinguishes for
any reason. To re-ignite, wait 30 seconds for any
unburnt gas to disperse before repeating the ignition
procedure described above.
To turn off the gas supply to a burner turn the control
knob clockwise to the ‘OFF’ position. (Refer Fig. 14)
The control knob is used to adjust the flame of the gas
burner.
‘Low flame’ graphic = lowest output
‘High flame’ graphic = highest output
Operating instructions
1. Medium burner
2. Medium burner
3. Wok burner
5. Small burner
Burner ignition &
control
Preparing to install
Burner locations
13
14