12. OPTIONS
12 - 1
P/N 0191914
T
AC GENERATOR
C A U TIO N
Do not use the AC GENERATOR unless the
hydraulic oil is over 70°F (21°C). The output
voltage of the generator depends on the
temperature of the hydraulic oil. Temperature
below 70°F (21°C) will cause dangerously low
output voltages that can burn out some kinds of
electrical equipment.
The hydraulically powered, 120 V ac generator
can be used anytime the TB120 engine is
running and the TB120 is completely stationary.
Turning the generator on stops all machine
movement.
Set the MACHINE/GENERATOR switch (1) to
GENERATOR and a total of 2 kW, continuous
duty, 120 V ac power is available from the two
electrical outlets (2) under the platform-control
box or the electrical outlet on the end of the
generator housing.
NOTE: To energize the two platform electrical
outlets, the power cord (3) from the platform
outlets must be plugged into the receptacle on
the generator (4).
T
AIR LINE TO PLATFORM
The input to the air line is on the bottom left-rear
of the turntable.
The outlet is on the platform mounting frame.
The maximum safe
working pressure for the
air line is 250 psi (1725 kPa).
12. OPTIONS