Operation
18
A46JRT – 0260228
Only use the emergency power system if the main power
system fails.
Lower Controls
Use the following procedure to operate the machine using
the emergency power system from the lower controls.
1. Place the battery disconnect switch in the on posi-
tion.
2. Place the key in the control selector switch and turn
it to the ground position.
3. Pull the emergency stop button outward.
4. Hold the ground operation switch in the on position
while holding the engine/emergency power switch in
the emergency power position.
5. Hold the appropriate function toggle switch in the
desired direction.
Upper Controls
For the upper controls to be operational:
The battery disconnect switch must be in the on
position.
The emergency stop button at the lower controls must
be in the on position.
The control selector switch at the lower controls must
be in the platform position.
•
•
•
Use the following procedure to operate the machine using
the emergency power system from the upper controls.
1. Pull the emergency stop button outward.
2. Turn the start switch on.
3. Step down on the platform foot switch.
4. Hold the engine/emergency power switch in the
emergency power position.
5. Hold the appropriate function toggle switch in the
desired direction.
After Use Each Day
1. Ensure that the platform is fully lowered.
2. Park the machine on a firm level surface, preferably
under cover, secure against vandals, children and
unauthorized operation.
3. Turn the Chassis Key Switch to OFF and remove the
key to prevent unauthorized operation.