Controls and Indicators

8

A46JRT – 0260228

Hold the switch downward to lower the jib.

Platform Level Switch

The platform level switch (refer to Figure 3) is used to level

the platform floor with respect to the ground. The switch

is spring returned to the center off position.

Hold the switch upward to tilt the platform floor upward

or away from the ground.

Hold the switch downward to tilt the platform floor

downward or toward the ground.

Platform Rotation Switch

The platform rotation switch (refer to Figure 3) is used to

rotate the platform relative to the end of the tip boom. The

switch is spring returned to the center off position.

Hold the switch to the right to rotate the platform

counterclockwise.

Hold the switch to the left to rotate the platform clock-

wise.

Engine/Emergency Power Switch

The engine/emergency power switch (refer to Figure 3)

is used to operate turntable, boom, and platform func-

tions using the emergency power system. The switch is

spring returned to the engine position for aerial platform

engine operation.

Caution

The emergency power system is for emergency low-

ering and stowing only. The length of time the pump

can be operated depends on the capacity of the bat-

tery. Do not use this system for normal operation.

Hold the engine/emergency power switch downward

in the direction of the white arrow to activate the

emergency power system.

Release the switch to disengage the emergency power

system.

If the engine is running, it will stop when the switch is

placed in the emergency power position.

Hydraulic Oil Warm-Up Switch

The optional hydraulic fluid warm-up switch is used to

warm the hydraulic fluid when the ambient temperature

is below 0°C (32°F) and boom movement is sluggish

because of cold fluid.

Caution

Not all hydraulic fluid is suitable to use in the hydrau-

lic system. Some have poor lubricating character-

istics and may increase component wear. Only use

hydraulic fluid as recommended.

Use cold weather hydraulic oil as recommended in the

machine General Specifications in temperatures of 0°C

(10°F) or below.

The toggle switches for the warm-up system are on the

lower control panel and on the front of the upper control

panel.

Note

Machine functions are not operational while using the

hydraulic warm-up system.

To warm-up the hydraulic fluid from the lower controls:

1. Start the engine from the lower controls.

2. Place the hydraulic fluid warm-up switch in the on

position.

The engine throttle speed will increase to warm the

hydraulic fluid.

The engine throttle speed will decrease and return

to idle once the hydraulic fluid reaches a preset

temperature.

If the warm-up switch is left on the engine speed

will continue to increase and decrease to keep the

hydraulic fluid at a preset temperature.

3. When the engine throttle speed returns to idle, place

the hydraulic fluid warm-up switch in the off position.

Circuit Breaker Reset Buttons

The lower control panel electrical system has a 10 amp

circuit breaker for both the internal relays and the toggle

switches, and a 25 amp circuit breaker for the main

control system circuit. There is a reset button for each

circuit breaker at the top of the lower control panel (refer

to Figure 3).

The upper control panel has a 10 amp circuit breaker for

the upper control system circuit, with the reset button on

the front of the upper control panel (refer to Figure 4).

The electrical power outlet at the platform has a 15 amp

circuit breaker. The reset button is on the left side of the

electrical box.

The battery disconnect panel has a 15 amp circuit breaker

for the engine throttle circuit and a 25 amp circuit breaker

for the glow plug circuit. The reset buttons are on the bot-

tom right side of the battery disconnect panel.

The circuit breakers protect the electrical wiring and

components from electrical overload in case of a short

circuit or other fault.

Caution

A tripped circuit breaker indicates a malfunction in

the electrical system. Component damage can result

if the cause of the malfunction is not corrected. Do

not operate the aerial platform if the circuit breaker

trips repeatedly.

Push the button to reset the circuit breaker.