Lukas – Lukas PC 650 User Manual
Page 39

39
Fault
Check
Cause
Solution
It is frequently not
possible to couple
hose assemblies
Hydraulic fl uid not
adapted to the
application situation
Hydraulic fl uid must be
replaced (see chapter
“Recommended
Hydraulic fl uids”)
Coupling defective
Coupling must be
replaced immediately
Leak from the
couplings
Coupling defective
Coupling must be
replaced immediately
Fluid leak on the
hoses or the fi ttings
Leak, possible damage Replace hoses
Damages on the
surface of the hoses
Mechanical damage
or contact with
aggressive agents
Replace hoses
Contact an authorised LUKAS dealer or the LUKAS Customer Service Department directly
if the malfunctions cannot be rectifi ed.
The address for the LUKAS Customer Service department is:
LUKAS
Hydraulik GmbH
A unit of the IDEX Corporation
Weinstrasse 39, D-91058 Erlangen, Germany
Tel.: (+49) 09131 / 698 - 348
Fax.: (+49) 09131 / 698 - 353