Fault
Check
Cause
Solution
Fluid coming out of
hydraulic fl uid tank
Connected
unit not in rest
position yet and
fl uid coming out
of fi ller cap?
Returning the
hydraulic fl uid from the
equipment exceeds
the tank’s maximum
capacity.
Reduce fl uid level in
the hydraulic tank to
“Minimum” (bottom
sight glass), move
the unit to the base
position and then fi ll
back up with hydraulic
fl uid to the “Maximum”
level (top sight glass)
Fluid leaks from a
different location?
Leak from tank, lines
or seals
Replace defective
components or repair
by authorised dealer or
Lukas directly
Leaking fl uid
between engine and
fl ange bearing
Radial shaft seal
on the drive shaft is
defective
Have it repaired by
authorised dealer or
directly by LUKAS
Hydraulic fl uid milky
and cloudy
Water / condensation
in the system
Replace the hydraulic
fl uid immediately
Hoses cannot be
coupled
Pressure too high (e.g.
caused by ambient
temperature too high)
Switch valve block to
circulation at static
pressure
Coupling defective
Coupling must be
replaced immediately
Carrying handles
cannot be pulled out
or pushed in.
Carrying handles are
still locked
Unlock the carrying
handles and then pull
them out.
Carrying handles or
frame defective
Replace the carrying
handles or the frame.
Carrying handles
cannot be locked or
unlocked
Carrying handles or
frame defective
Replace the carrying
handles or the frame.
Hose reel does not
turn
Holding brake still
active
Release the holding
brake
Hose reel defective
Have it repaired by
authorised dealer or
directly by LUKAS
Equipment cannot
be fi xed on the
equipment shelf
Equipment shelf set
incorrectly
Reset the equipment
shelf to suit the
equipment.
Equipment shelf
defective
Replace equipment
shelf.