12 troubleshooting – Lukas LZR 12-700 EN User Manual
Page 12
12
11.3.2 Set of identification stickers
All damaged or illegible indentification stickers (Safety instructions, type label a.s.o) have to be
replaced.
Procedure:
Remove damaged stickers and clean surface with acetone • Put on new stickers.
11.3.3 Quick couplers
Quick couplers on the 0,5m hoses have to be replaced when
- external damage can be observed,
- the locking sleeve doesn´work any more,
- oil spill occurs even when the coupling is properly connected.
Remark: Faulty couplers have to be changed completely against genuine LUKAS spares, i.e. it
is not permissible to make any repair work.
The retaining nut on the hoses has to be tightened with a torque of M
A
= 45 Nm
12 Troubleshooting
If the defects cannot be repaired, contact an authorised LUKAS dealer or the LUKAS service department.
The address:
LUKAS Hydraulik GmbH, Weinstraße 39, D-91058 Erlangen, Pf 2560, D-91013 Erlangen, service phone
09131/698 348; fax 09131/698 353.
Trouble
Check
Cause
Remedy
Hoses cannot be
Pressurized
Relieve pump pressure
coupled
On actuating pistons
Hoses correctly
Air in the hydraulic
Thoroughly vent pump
move slowly or by
connected power
system
unit: see 8.1.1
jerks
pack operating
No pressure build-up
Not enough oil in hand
Refill oil and vent the
resp. motor pump.
system (see operating
Vent pumpe after
instruction 8.1.1)
changing oil
Star grip doesn't return
Return spring is
Ask authorized dealer or
to middle position when
damaged or return
LUKAS themselves
released
mechanism is dirty
Oil leakage out of
Untightness, eventually
Replace hoses
hoses or hose fittings
damages
Surface of hydraulic
Contact with
Change hoses
hoses is dissolved
agressive fluids
Leakages on the
Seal defective piston
Replacement of seals
piston rod
rod
by authorized dealer or
LUKAS themselves