beautypg.com

Technical data – Bosch WTL 5410 User Manual

Page 17

background image

17

Technical Data

WTA 3510: 88 lbs. (40 kg) – with packaging

1

99 lbs. (45 kg)

WTL 5410: 99 lbs. (45 kg) – with packaging 110 lbs. (50 kg)

22

1

/

4

’’

(565 mm)

23

5

/

8

’’

(600 mm)

33

1

/

2

’’ (850 mm)

adjusts to

34

1

/

2

’’ (876 mm)

Figure 12.

Electrical Requirements

The Bosch dryers should be CONNECTED TO AN 30A
INDIVIDUAL BRANCH CIRCUIT. North American
models have the following electrical rating:

Model

Volts

Hertz

Amperes

Watts

(max.)

WTA
3510

208/240

60

13

3,100

WTL

5410

208/240

60

13

3,100

Check the rating plate on the dryer to make sure your
machine has this rating.

Choosing the Location

The dryer should not be installed:

l

in an area exposed to dripping water or outside
weather conditions

l

in an area where it (and in the case of the WTA 3510,
its exhaust duct) will come in contact with
combustible materials, such as curtains, drapes
or paper.

l

in areas where water may freeze

l

in an area where gasoline or other flammables are
kept or stored.

Check local codes before choosing a location. Some
codes do not permit installation of a clothes dryer in
a garage, closet, mobile home or sleeping area. Your
local building inspector should be able to advise you of
the codes in your area.

Minimum Installation Clearances

Alcove or Under

Counter

Closet

Sides

0’’ (

0

0 mm)

0’’ (

00

0 mm)

Top

0’’ (

0

0 mm)

10’’ (250 mm)

Rear

1’’ (25 mm)

5’’ (125 mm)

Ventilation Requirements

Alcove or

Under

Counter

Closet

WTA
3510

Ensure air flow

of

112 cu.ft./min

(3,2 cu.m./min)

through dryer

Closet door must have

2 (louvered) openings,

each having a minimum

area of 60 sq. inches

(387 sq. cm.), located

3 inches (8 cm) from

bottom and top of door. *

WTL

5410

Ensure air flow

of

118 cu.ft./min

(3,3 cu.m./min)

through dryer

Closet door must remain

open during dryer

operation.

*

A louvered door with equivalent air opening
is acceptable.

Flooring

The dryer should be installed on a level, solidly
constructed floor. DO NOT install the dryer on
a carpeted floor.