SERVICING INSTRUCTIONS (continued)

IMPORTANT:

Water pressure

must be between 20 p.s.i and
90 p.s.i. flowing pressure.
If water pressure exceeds this
value, or if water pressure
varies greatly, a pressure
regulator must be installed in
the water supply line.





IMPORTANT:

Before setting

assembly into tank, make sure
tank lid gasket is properly
seated on flange of lid.
DO NOT OVER-TIGHTEN

.











IMPORTANT:

When mounting

thermostat, be sure a new seal
washer is placed below the
fitting on the capillary line.
Push sensing bulb thru tank lid
until fitting seats.
Tighten capillary lock nut only
enough to ensure no water
leakage. Excessive tightening
is not necessary.


IMPORTANT:

When replacing

heating element, also replace
seal gaskets.




TIMER ADJUSTMENT

The amount of water dispensed automatically during a brew cycle
is controlled by the timer.

Place empty decanter under brew chamber. Press BREW
button. Brewer should dispense one decanter of water. To
adjust amount:

Remove brew chamber and button plug. Adjust knob on timer;
clockwise increases time. Run several cycles to check amount of
water delivered. Replace button plug.

REMOVE TANK LID ASSEMBLY

Unplug brewer or turn circuit breaker OFF. Turn OFF water
supply. Remove top panel. Pull vent tube and inlet elbow out of
basin pan.

Pull water inlet tube out of basin pan. Remove basin pan.

On models with faucet, disconnect inlet pipe at faucet shut-off
valve and outlet pipe at faucet.

Disconnect all wiring from thermostat, hi-limit, and heating
element.

Loosen center screw on tank hold-down bracket. Remove
hold-down bracket by sliding short slotted end off of locking stud
and lifting it off. Remove cover assembly by lifting it straight up.

Reassemble in reverse order.

REPLACE THERMOSTAT

Unplug brewer or turn circuit breaker OFF. Turn OFF water
supply. Remove top panel.

Disconnect all wiring from thermostat only. Loosen and free jam
nut from pass-thru fitting securing temperature sensing bulb.
Remove two screws holding thermostat to bracket.

Lift out thermostat, sensing bulb and thermostat gasket.

Reassemble in reverse order.

REPLACE HEATING ELEMENT

Remove tank lid assembly per above.

Remove two hex nuts holding element to cover. Pull element
from mounting holes.

Reassemble in reverse order.